CP-511 pH/mV Bench Meter + IJ Electrode

$1,280.00

  • Simple laboratory meter.
  • Measures pH, redox potential (ORP) and temperature.
  • The display enables simultaneous readout of the measured function and temperature.
  • pH electrode calibration in 1 to 3 constant points (4.00, 7.00, 9.00 pH).
  • Automatic detection of the pH buffer solution value.
  • Memory of 50 results.
  • No PC connection.

Available on back-order

SKU: ELCP-511-IJ Categories: ,

Description

CP-511 pH/mV Bench Meter + IJ Electrode

Detailed description

Accurate and easy in use laboratory meter used for pH, mV (redox potential) and temperature measurements.

Characteristic features:

  • Large easy to read LCD display
  • Simultaneous readout of the measured function and temperature value.
  • Calibration of the pH electrode: 1 ÷ 3 points 4.00, 7.00, 9.00 or optionally 4.00, 7.00, 10.00 pH.
  • Automatic buffer detection.
  • Automatic temperature compensation.
  • Depending on the kind of applied pH electrode may be used for measurements of clean water, waste water, meat, cheese, pastes, soil etc.
  • Possibility to check the electrode condition (buffer and slope).
  • Memory of 50 results.
  • Wide temperature measurement range.
  • IP64 ingress protection.
  • 24 months of warranty for the meter.

The standard set includes CT2B-121 temperature probe with Pt-1000B resistor and EPS-1 pH electrode for measurements in clean water. It should not be used in other types of liquids. Measurements in liquids with sediments should be made with use of IJ-44A pH electrode. Its unusual construction ( ”intermediate junction”) protects the real junction (diaphragma) of the electrode against clogging, ensures stable measurements in these types of liquids or semi-liquid masses, in which other electrodes stop working quickly. When properly handled and maintained, the electrode’s lifetime is longer than the standard electrodes.

TECHNICAL DATA

Function pH Redox / mV Temperature
Range -2.00 ÷ 16.00 pH ± 1999 mV -50.0 ÷ 199.9 °C
Resolution 0.01 pH 1 mV 0.1 °C
Accuracy (±1 digit) ±0.01 pH* ±1 mV* ±0.1 °C**
Temp compensation -5 ÷ 110 °C
Input impedance >1012Ω >1012Ω
Power supply 12 V / 100 mA power adapter
Weight 560 g
Dimensions (mm) L = 200, W = 180, H = 20/50
* The accuracy of the meter only.
** The accuracy of the meter only. The total error includes the meters and probe’s accuracy. In the range 0 ÷ 100 °C the acceptable error of the probe with Pt-1000B resistor: ±0.8 °C, with Pt-1000A resistor: ±0.35 °C.

 

CP-511