CP-511 pH/mV Bench Meter + IJ Electrode
$1,280.00
- Simple laboratory meter.
- Measures pH, redox potential (ORP) and temperature.
- The display enables simultaneous readout of the measured function and temperature.
- pH electrode calibration in 1 to 3 constant points (4.00, 7.00, 9.00 pH).
- Automatic detection of the pH buffer solution value.
- Memory of 50 results.
- No PC connection.
Available on back-order
Description
CP-511 pH/mV Bench Meter + IJ Electrode
Detailed description
Accurate and easy in use laboratory meter used for pH, mV (redox potential) and temperature measurements.
Characteristic features:
- Large easy to read LCD display
- Simultaneous readout of the measured function and temperature value.
- Calibration of the pH electrode: 1 ÷ 3 points 4.00, 7.00, 9.00 or optionally 4.00, 7.00, 10.00 pH.
- Automatic buffer detection.
- Automatic temperature compensation.
- Depending on the kind of applied pH electrode may be used for measurements of clean water, waste water, meat, cheese, pastes, soil etc.
- Possibility to check the electrode condition (buffer and slope).
- Memory of 50 results.
- Wide temperature measurement range.
- IP64 ingress protection.
- 24 months of warranty for the meter.
The standard set includes CT2B-121 temperature probe with Pt-1000B resistor and EPS-1 pH electrode for measurements in clean water. It should not be used in other types of liquids. Measurements in liquids with sediments should be made with use of IJ-44A pH electrode. Its unusual construction ( ”intermediate junction”) protects the real junction (diaphragma) of the electrode against clogging, ensures stable measurements in these types of liquids or semi-liquid masses, in which other electrodes stop working quickly. When properly handled and maintained, the electrode’s lifetime is longer than the standard electrodes.
TECHNICAL DATA
Function | pH | Redox / mV | Temperature |
---|---|---|---|
Range | -2.00 ÷ 16.00 pH | ± 1999 mV | -50.0 ÷ 199.9 °C |
Resolution | 0.01 pH | 1 mV | 0.1 °C |
Accuracy (±1 digit) | ±0.01 pH* | ±1 mV* | ±0.1 °C** |
Temp compensation | -5 ÷ 110 °C | – | – |
Input impedance | >1012Ω | >1012Ω | – |
Power supply | 12 V / 100 mA power adapter | ||
Weight | 560 g | ||
Dimensions (mm) | L = 200, W = 180, H = 20/50 |
* | The accuracy of the meter only. |
** | The accuracy of the meter only. The total error includes the meters and probe’s accuracy. In the range 0 ÷ 100 °C the acceptable error of the probe with Pt-1000B resistor: ±0.8 °C, with Pt-1000A resistor: ±0.35 °C. |