FLUKE 116/62 MAX + HVAC TECHNICIANS COMBO KIT

$891.00

Combine the power of Fluke’s 116 HVAC Multimeter with a Fluke 62 MAX+ infrared thermometer for productive and effective troubleshooting

Description

Having the right tool for the job is essential. Having all the right tools when you need them is even better.

The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations.

Fluke 116 multimeters are independently tested for safe use in CAT III 600V environments.

The Fluke 62 MAX+ infrared thermometer is everything you’d want in your toolbox. Small in size, extremely accurate and yet easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop.

Together, the Fluke 116 HVAC Multimeter and 62 MAX+ Infrared Thermometer give HVAC technicians the right tools for the job.

Features

Fluke 116 HVAC Multimeter

  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance helps prevent false readings due to ghost voltage
  • Work in poorly lit areas with the Large white LED backlit display
  • True-rms voltage and current for accurate measurements on non-linear loads
  • Measures 10 A directly (20 A overload for 30-seconds) without a current clamp
  • Resistance, continuity, frequency and capacitance
  • Record signal fluctuations using Min/Max/Average and elapsed time stamps
  • Easy to use with one hand
  • Hands free operation with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated

Fluke 62 MAX+ Infrared Thermometer

  • Measure -30°C to 650°C (-22°F to 1202°F)
  • Extremely accurate: up to +1.0°C or + 1.0% of reaching (Fluke 62 MAX+)
  • IP54 rating for water resistance and dust proof allow you to work rain or shine and even in the most dirty or dusty industrial sites
  • Strong enough to withstand a 3m drop. No worry even if you work from a ladder
  • Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box
  • Dual lasers: The 62 MAX+ has dual lasers to help you identify area to be measured

Includes:

  • Fluke 116 HVAC Multimeter with Temperature and Microamps
  • Fluke 62 MAX+ Infrared Thermometer
  • TL175 Test Lead Set
  • TPAK Magnetic Hanging Kit
  • 80BK-A Thermocouple Probe
  • 80AK-A Thermocouple Probe
  • Flexible Cuff Pipe Clamp Thermocouple
  • C115 Soft Carrying Case

Specifications

Fluke 116 Multimeter

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10°C to +50°C
Storage Temperature -40°C to +60°C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/Resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS Range 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5% + 2
Diode Test Range/Resolution 2.000 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40°C to 400°C / 0.1°C
Accuracy2 1% + 10
Range/Resolution -40°F to 752°F / 0.2°F
Accuracy2 1% + 18
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Warranty 3 years

 

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range -30°C to 650°C (-22°F to 1202°F)
Accuracy ±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%) < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical resolution 12:1 (calculated at 90% energy)
Display resolution 0.1°C (0.2°F)
Repeatability of readings ±0.5% of reading or <±0.5°C (1°F), whichever is greater
Power AA battery
Battery life 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity 10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
IP rating IP 54 per IEC 60529
Drop test 3 meters
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006
Standards and agency approval Compliance EN/IEC 61010-1: 2001
Laser safety FDA and EN 60825-1 Class II