FLUKE 175 DIGITAL MULTIMETER
$589.60
Description
The Baseline for Industrial Measurements
The Fluke 175 True RMS Digital Multimeter is the baseline for professional technicians around the world. With features you need to troubleshoot and repair in electrical and electronic systems, the Fluke 175 CAT IV 600V/CAT III 1000 V digital multimeter provides accurate, True RMS readings through years of reliable service.
Features:
- Manual and automatic ranging
- Display Hold and Auto Hold
- Frequency and capacitance measurements
- Resistance, continuity and diode measurements
- Min-max-average recording
- Closed case calibration through front panel
- Ergonomic case with integrated protective holster
Safety conformance
All inputs are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed and VDE Pending
Includes:
- Installed 9V battery
- Test leads
- Users manual
Specifications:
Voltage DC | Accuracy1 | ±(0.15% + 2) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Voltage AC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Current DC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Current AC | Accuracy1 | ±(1.5% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Resistance | Accuracy1 | ±(0.9% + 1) |
Max. resolution | 0.1 Ω | |
Maximum | 50 MΩ | |
Capacitance | Accuracy1 | ±(1.2% + 2) |
Max. resolution | 1 nF | |
Maximum | 10,000 µF | |
Frequency | Accuracy1 | ±(0.1% + 1) |
Max. resolution | 0.01 Hz | |
Maximum | 100 kHz | |
1. Accuracies are best accuracies for each function | ||
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -30°C to +60°C | |
Humidity (without condensation) | 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 50°C) |
|
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III EN 61010–1 to 600 V CAT IV |
|
Agency approvals | UL, CSA, TÜV listed and VDE Pending | |
Mechanical and General Specifications | ||
Size | 43 x 90 x 185 mm | |
Weight | 420 g | |
Warranty | Lifetime | |
Battery life | Alkaline ~200 hours typical, without backlight |