FLUKE 374 FC TRUE-RMS AC/DC CLAMP METER
$750.20
Description
The Fluke 374 FC is part of the Fluke Connect family of wireless test tools. Now you can:
- Trend measurements and pinpoint intermittent faults by connecting your meter to your phone via Fluke Connect® Measurements app
- Transmit results wirelessly via Fluke Connect® Measurements app
- Create and send reports right from the field
- Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices
Features:
- Connect your meter to your smartphone with Fluke Connect Measurements
- Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
- Record results directly to your phone and the Cloud
- Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
- Compatible with iFlex flexible current probe; use to expand the measurement range to 2500 A ac; provides access to large conductors in tight spaces
- Compatible with TPAK magnetic hanging strap
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- CAT IV 600 V, CAT III 1000 V safety rating
- Three-year warranty
- Soft carrying case
Measurement Capability
- 600 A ac and dc current measurement
- 2500 A ac current measurement with (optional) iFlex flexible current probe
- 1000 V ac and dc voltage measurement
- True-rms voltage and current for accurate measurements on non-linear signals
- Resistance measurement to 6000 Ω with continuity detection
- Min, max, average, and inrush recording to capture variations automatically
- 1000 μF capacitance measurement
Includes:
- Soft carrying case
- TL75 test leads
- Two AA Alkaline batteries
- Coated instruction card
- Safety information sheet
Specifications:
AC Current via Jaw | |||
Range | 600.0 A | ||
Resolution | 0.1 A | ||
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | ||
2.5% ±5 digits (100-500 Hz) | |||
Crest Factor (50 Hz/60 Hz) | 2.5 @ 600 A | ||
Add 2% for C.F. >2 | |||
AC Current via Flexible Current Probe | |||
Range | 2500 A | ||
Resolution | 0.1 A (≤ 600 A) | ||
1 A (≤ 2500 A) | |||
Accuracy | 3% ±5 digits (5 – 500 Hz) | ||
Crest Factor (50/60Hz) | 2.5 at 1400 A | ||
1.42 at 2500 A | |||
Add 2% for C.F. > 2 | |||
Position Sensitivity | |||
i2500-10 Flex | i2500-18 Flex | ||
A | |||
Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | |
Error | ±0.5 % | ±0.5 % | |
B | |||
Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | |
Error | ±1.0 % | ±1.0 % | |
C | |||
Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | |
Error | ±2.0 % | ±2.0 % | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | |||
DC Current | |||
Range | 600.0 A | ||
Resolution | 0.1 A | ||
Accuracy | 2% ±5 digits | ||
AC Voltage | |||
Range | 1000 V | ||
Resolution | 0.1 V (≤600.0 V) | ||
1 V (≤1000 V) | |||
Accuracy | 1.5% ±5 digits (20 Hz to 500 Hz) | ||
DC Voltage | |||
Range | 1000 V | ||
Resolution | 0.1 V (≤600.0 V) | ||
1 V (≤1000 V) | |||
Accuracy | 1% ±5 digits | ||
mV dc | |||
Range | 500.0 mV | ||
Resolution | 0.1 mV | ||
Accuracy | 1% ±5 digits | ||
Resistance | |||
Range | 6000 Ω | ||
Resolution | 0.1 Ω (≤600 Ω) | ||
1 Ω (≤6000 Ω) | |||
Accuracy | 1% ±5 digits | ||
Capacitance | |||
Range | 1000 μF | ||
Resolution | 0.1 μF (≤ 100 μF) | ||
1 μ F (≤ 1000 μF) | |||
Accuracy | 1% ±4 digits | ||
Mechanical Specifications | |||
Maximum voltage between any terminal and earth ground | 1000 V | ||
Batteries | 2 AA, NEDA 15A, IEC LR6 | ||
Operating temperature | -10 °C to +50 °C | ||
Storage temperature | -40 °C to +60 °C | ||
Operating humidity – non-condensing (< 10°C) |
≤90% RH (at 10 °C to 30 °C) | ||
≤75% RH (at 30 °C to 40 °C) | |||
≤45% RH (at 40 °C to 50 °C) | |||
Operating altitude | 3000 m | ||
Storage altitude | 12,000 m | ||
Size (L x W x H) | 249 x 85 x 45 mm | ||
Weight | 395 g | ||
Jaw opening | 34 mm | ||
Flexible current probe diameter | 7.5 mm | ||
Flexible current probe cable length (head to electronics connector) |
1.8 m | ||
Safety | IEC 61010-1, Pollution Degree 2 | ||
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | |||
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | |||
IP rating | IEC 60529: IP30, non-operating | ||
Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE | ||
Electromagnetic Compatibility (EMC) | |||
International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 | ||
CISPR 11: Group 1, Class A | |||
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | |||
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. | |||
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | ||
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |||
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | ||
Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |